KBWF 720 (E5.1)
Plant growth chamber with optimal climatic conditions

KBW_240

The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect interaction between heat or cold, humidity and light. This wide climatic range can simulate any climatic condition precisely and constant over extended periods of time, including natural lighting conditions and day-night simulation.

  • Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
  • Temperature range: -5 °C to 100 °C (23 °F to 212 °F) without humidity and illumination
  • Temperature range: 20 °C to 90 °C (68 °F to 194 °F) with humidity respective illumination
  • Humidity range 10 % - 90 % RH
  • MCS controller for temperature, humidity, and illumination with 25 storable programs of 100 sections each for a maximum of 500 program segments, for programming day/night cycles
    - User friendly LCD screen
    - Easy-to-read menu guide
    - Integrated electronic chart recorder
    - Variety of options for the graphic display of process parameters
    - Real-time clock
  • Illumination system with daylight fluorescent tubes in the doors, thermally isolated from the inner chamber and ventilated (optimized illumination)
  • Controlled humidification and dehumidification system with capacitive humidity sensor using tap water
  • Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm
  • Access ports Ø 30 mm (1.18 inch), right side, top and bottom
  • Environmental friendly refrigerant R 134a
  • Inner glass door
  • Complete safety connection kit for water supply and drainage, including water hose, total length 6 m (19.7 ft.)
  • RS 422 interface for GLP/GMP and FDA guideline 21 CFR Part 11 compliant APT-COM™ DataControlSystem software
  • 2 stainless steel racks included
  • BINDER test certificate

 

 

 

Technical Specifications

 

Exterior dimensions

 

Width (mm/inch)

1234 / 48.6

Height (inclusive castors) (mm/inch)

1816 / 71.5

Depth (mm/inch)

867 / 34.1

Plus door handle, I-panel, connection (mm/inch)

100 / 3.9

Wall clearance rear (mm/inch)

100 / 3.9

Wall clearance side (mm/inch)

160 / 6.3

Steam space volume (l/cu.ft.)

855 / 30.2

Height of water connections (±3 mm/±0.12 inch) (mm/inch)

190 / 7.5

Number of doors

2

Number of inner glass doors

2

Interior dimensions

 

Width (mm/inch)

1000 / 39.4

Height (mm/inch)

1168 / 46.0

Depth (mm/inch)

600 / 23.6

Interior volume (l/cu.ft.)

700 / 25.1

Racks (number standard / max.)

2 / 14

Load per rack (kg/lbs.)

45 / 99

Permitted total load (kg/lbs.)

120 / 265

Weight (empty) (kg/lbs.)

345 / 762

Temperature data

 

Temperature range

 

without humidity / without illumination (°C/°F)

-5 - 100 / 23 - 212

with humidity / with illumination (°C/°F)

5 - 100 / 41 - 212

with humidity / without illumination (°C/°F)

20 - 90 / 68 - 194

with humidity / with illumination (illumination in the door) (°C/°F)

20 - 90 / 68 - 194

Temperature variation

 

without humidity at 10 °C (50 °F) (± °C)

0.4

without humidity at 37 °C (98.6 °F) (± °C)

0.4

with humidity (± °C)

1.0

Temperature fluctuation during heating operation (± °C)

0.1

Temperature fluctuation during cooling operation (± °C)

0.5

Heating up time 1) to 37 °C (98.6 °F) (Min.)

28

Cooling down time from room temperature 1), 2) to 10 °C (50 °F) (Min.)

35

Recovery time after door was open for 30 sec 1), 2)

 

at 37 °C (98.6 °F) (Min.)

5

at 50 °C (122 °F) (Min.)

4

Humidity fluctuation 3) (± % RH)

1.5

Illumination data /Light intensity

 

Daylight fluorescent tubes, light color 865 (distance of measuring level to the glass door: 12 cm) (LUX)

16.600

Daylight fluorescent tubes, light color 865 (distance of measuring level to the glass door: 12 cm) (µE/S x m²)

250

OPTION Fluora® growth lamps, light color 77 (distance of measuring level to the glass door: 12 cm) (LUX)

7.500

OPTION Fluora® growth lamps, light color 77 (distance of measuring level to the glass door: 12 cm) (µE/S x m²)

164

OPTION additional illumination under the ceiling, daylight lamps light color 865 (LUX)

19.000

Electrical data

 

Housing protection acc. to EN 60529

IP 20

Nominal voltage (±10 %) 50 / 60 Hz (V)

230 1N~

Nominal power (kW)

2.95

Energy consumption 4) at 37 °C (98.6 °F) (W)

970

 

 

 

Contact us on 01939 291200 or by email info@sciquip.co.uk