Assay Furnace N 110/HS and S 73/HS

N 110/HS with manual lift door and integrated control cabinet

 

Customized pit-type furnace S 73/HS, with rolling lid for bigger charges in crucibles

 

 


Work platform in front of muffle to
place load

Furnace chamber of S 73/HS with SiC-plates as muffle function

N 110/HS

The N 110/HS furnace is especially used for the assay of precious metals where the insulation and heating must be protected from emerging gasses and vapours. The furnace chamber forms a ceramic muffle which can easily be replaced. In the standard design, the muffle is closed with a firebrick plug. A lift door can be installed instead upon request.

  • Tmax 1300 °C
  • Muffle heated from four sides
  • Heating elements and insulation protected by ceramic muffle
  • Simple replacement of muffle
  • Manual lift door
  • Tool holder on furnace
  • Stainless steel exhaust chimney above the door opening for connection of an exhaust system
  • Work platform with embedded ceramic plate in front of the muffle opening to place load
  • Front side with large service door for easy access to the furnace chamber behind the muffle
  • Double-walled housing with fan cooling to reduce exterior temperatures
  • Base frame with integrated switchgear and controller

Additional equipment

  • Electrical lift door drive with 2-hand button operation
  • Second work platform with embedded ceramic plate below the standard platform

 

 

Technical Specifications
ModelTmax
°C
Interior dimensions in mmVolume
in L
Outer dimensions in mmPower
kW
Electrical
connection
Weight in kg
w d h W D H
N 110/HS 1300 260 340 95 8 760 790 1435 22 3-phase 510
S 73/HS12005303803607310501530900263-phase890

 

¹Heating only between two phases
²External dimensions of furnace, transformer in separate housing (500 x 570 x 300 mm)
³Switchgear and controller mounted in a floor standing cabinet

 

 

 

Contact us on 01939 291200 or by email info@sciquip.co.uk