- Centrifuges
- Centrifuge Tubes
- Chillers
- Climatic Chambers
- Cloning Cylinders
- CO2 Incubators
- Centrifugal Concentrators
- Flasks
- Freeze Dryers
- Furnaces
- Hungate Tubes
- Incubators
- Incubated Shakers
- Liquid Handling
- Microfuges
- Ovens
- Pipettors
- Plant Growth Chambers
- Roll-in Incubators/Rollers
- Shaking Incubators
- Shakers
- Sterilization Chambers
- Stirrers/Mixers
- Tensiometers
- Test Chambers
- Spinner Flasks
- Vacuum Ovens
- Vacuum Concentrators
- Vacuum Pumps
- Viscometers
- Water Baths/Thermostats
DUROCELL with natural air convection

Special – purpose drying ovens DUROCELL with highly resistant EPOLON-coating, protecting the internal chamber of aggressive substances like acids or alkaline liquids. This device ensures an optimum goods temperature equalisation. It is ideal for acid and basic hydrolysis, extranction of non-inflammandle materials and decomposition of substances in soild phase.
- Volume:
22, 55, 111, 222 litres - Working temperature:
5 °C above ambient temperature up to125 °C - Interior:
stainless steel, mat. No. 1.4301 (AISI 304)
The versatile standard line with microprocessor control unit

- 3 programs
- RS 232 - interface for printer or PC - communication
- delayed heating start and stop function
- acoustic and visual alarm
- time range 99 hours 59 minutes
- digital safety thermostat class 2
- manual control of the air exhaust flap
Options
- acess ports ø 25,50,100mm (ø 100mm is not available for 22-litres volume)
- door lock
- left door versions (excluded volume 22 litres)
- separate PT 100 – sensor
- communication software WarmComm
- stainless steel casing of the device
- measurement of material´s temperature with an independent movable sensor PT 100 (with indication on a display or PC)
The high-tech comfort line with multi-functional microprocessor control unit

- 6 programs
- chip card system for individual program storage
- RS 232 - interface for printer or PC - communication
- delayed heating start and stop function
- acoustic and visual alarm
- time range 0–16 years with 1 min-intervals
- digital safety thermostat class 2
- real time
- programming temperature ramps
- heating sequences
- programme cycles
- manual control of the air exhaust flap
Options
- access ports ø25,50,100mm (ø 100 mm is not available for 22-litres volume)
- door lock
- left door versions (excluded volume 22 litres)
- communication software WarmComm
- potential-free alarm contact
- measurement of material´s temperature with an independent movable sensor PT 100 (with indication on a display or PC)
- stainless steel casing of the device
Specifications
|
Model |
22 |
55 |
111 |
222 |
|
Interior of stainless steel material No. 1.4301 |
volume |
cca ltrs |
22 |
55 |
111 |
222 |
width |
cca mm |
240 |
400 |
540 |
540 |
|
depth |
cca mm |
320 |
390 |
390 |
540 |
|
height |
cca mm |
295 |
350 |
530 |
760 |
|
Trays
|
racks |
max. No. |
4 |
4 |
7 |
10 |
| standard equipment |
pcs. included |
2 |
2 |
2 |
2 |
|
distance between guide rails |
mm |
60 |
70 |
70 |
70 |
|
storage area (w x d) |
mm |
185x265 |
380x335 |
520x335 |
520x485 |
|
Maximal weight of the load*)
|
per tray |
max. kg |
10 |
20 |
20 |
30 |
inside the oven |
max. kg |
25 |
50 |
50 |
70 |
|
Door |
|
No. |
1 |
1 |
1 |
1 |
External dimensions (including door and handle)
|
width |
cca mm |
406 |
620 |
760 |
760 |
depth |
cca mm |
580 |
640 |
640 |
790 |
|
height (incl. Foots and Rolls) |
cca mm |
604F |
680F |
860F |
1090F |
|
diameter of the air branch outer/inner |
cca mm |
52/49 |
52/49 |
52/49 |
52/49 |
|
Package dimensions (three layers carton)
|
width |
cca mm |
465 |
700 |
830 |
830 |
depth |
cca mm |
665 |
730 |
730 |
860 |
|
height (incl. palette) |
cca mm |
655 |
880 |
1050 |
1280 |
|
Weight
|
netto |
max kg |
31 |
55 |
75 |
100 |
brutto |
max kg |
36 |
66 |
87 |
116 |
|
Working temperature (beginning of the regulation) |
|
from 5 °C above ambient temp. to °C |
125 |
125 |
125 |
125 |
Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door |
space deviation |
cca ( ±)% °C of the reached temperature |
2,7 |
2 |
2 |
2 |
time variation |
cca ± °C |
3,1 |
0,3 |
0,3 |
0,3 |
|
Time required to reach 100 °C with closed air flap and voltage 230 V |
|
cca min. |
34 |
41 |
48 |
50 |
Heat emission at 100 °C |
|
cca W |
140 |
380 |
490 |
630 |
Air exchange speed at 100 °C |
|
cca/h |
6 |
8 |
12 |
5 |
Electricity -mains 50/60 Hz
|
max. power input |
kW |
0,92 |
1,2 |
1,8 |
1,8 |
stand by |
W |
5 |
5 |
5 |
5 |
|
current |
A |
4,0 |
10,4 |
15,7 |
15,7 |
|
nominal voltage |
V |
115 |
115 |
115 |
115 |
|
*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.