STERICELL with forced air circulation

STERICELL is intended for hot air sterilization of materials under specified parameters of temperature and duration. It is characterized by quiet running with a patented fine system of forced air circulation in the chamber by means of a built-in fan which eliminates the “cold air” area formation. Loose and deposit-forming substances can be sterilized in closed bottles. The device is suitable for medical and veterinary clinics, hospitals, pharmacies, health care centres, and laboratories. Service providers like testing and beauty salons, body piercing studios, manicure, pedicure and hairdresser’s shops can take an ideal advantage of the 22-litre chamber of compact size and small weight. The device complies with the requirements of the EU Directive no. 93/42/EEC sincluding clinical evaluation.

  • Inner volume:
    22, 55, 111, 222, and 404 litres
  • Temperature range:
    From 10 °C above the ambient temperature up to 250 °C
  • Inner chamber:
    Stainless steel DIN 1.4301 (AISI 304).

 

Unique properties, safe operation

The temperature run is controlled by microprocessor automatics (Fuzzy-Logic) with a digital display and a PT 100 thermostat sensor. The microprocessor automatics ensure high accuracy of temperature regulation with a guaranteed thermal stability at each place of the sterilization chamber and the control of the door and air flap valve opening, which guarantees a higher safety of the individual sterilization procedures. STERICELL meets the highest demands for quality, speed, simple and comfortable operation, and safety. The individual sterilization batches records in real time can either be printed by means of a printer, or it can be saved in to PC using a special WarmComm software. The inner arrangement of the chamber allows a rearrangement of the screens or shelves, thus enabling as best use of the inner area as possible. STERICELL of 222 and 404 litres volume can be ordered either as a one-door or two-door (openthrough) model. It can be mounted in a wall between the contaminated and clean zone. We also offer the process and chemical indicators of the hot air sterilization to control the sterilization efficiency.

  • 3 preset sterilization programmes (possibility of a user modification by an authorized person)
  • Preset programmes blocking
  • Lagged programme switching-on function
  • Preheating time – settable duration of the equalization temperature of the load
  • Acoustic and visual alarm
  • Digital safety thermostat – protects the device, its surroundings and processed material from an inadmissible temperature rise
  • Manual control of the suction and exhaust flap
  • RS 232 interface for a printer or PC connection.

 

 

Optional accessories
  • Access ports ø 25, 50, and 100 mm (ø 100 mm is not available for 22-litres volume)
  • Lockable door
  • Left hinged door (except for the 22-litre volume)
  • 1 to 4 flexible PT 100 temperature sensors
  • WarmComm communication software
  • HEPA filter/HEPA pressure filter
  • No-potential contact for alarm messages
  • Two-door open-through model (222- and 404-litre versions only)
  • Automatic door blocking
  • Stainless steel casing of the unit

 

Specifications

 

 

Model

22

55

111

222

222/2**

404

404/2**

Interior of stainless steel material No. 1.4301

volume

cca ltrs

22

55

111

222

222/2

404

404/2

width

cca mm

240

400

540

540

540

540

540

depth

cca mm

320

390

390

540

540

540

540

height

cca mm

295

350

530

760

760

1410

1410

Trays

 

 

 

racks

max. No.

4

4

7

10

10

19

19

standard equipment

pcs. included

2

2

2

2

2

2

2

distance between guide rails

mm

60

70

70

70

70

70

70

storage area (w x d)

mm

185x265

380x335

520x335

520x485

520x485

520x485

520x485

Maximal weight of the load*)

 

per tray

max. kg

10

20

20

30

30

30

30

inside the oven

max. kg

25

50

50

70

70

100

100

Door

 

No.

1

1

1

1

2

1

2

External dimensions (including door and handle)

 

 

 

width

cca mm

406

620

760

760

760

760

760

depth

cca mm

560s/580c

640

640

790

806

790

806

height (incl. Foots and Rolls)

cca mm

604F

680F

860F

1090F

1110N

1910K

1910K

diameter of the air branch outer/inner

cca mm

52/49

52/49

52/49

52/49

52/49

52/49

52/49

Package dimensions (three layers carton)

 

 

width

cca mm

465

700

830

830

830

830

830

depth

cca mm

665

720

730

730

860

860

860

height (incl. palette)

cca mm

655

880

1050 

1280

1280

2070

2070

Mass

 

net

max kg

31

55

75

100

105

150

160

brut

max kg

36

66

87

116

121

175

185

Working temperature (beginning of the regulation)

 

from 10°C above ambient temp. to °C 

250

250

250

250

250

250

250

Temperature accuracy according to DIN 12 880 Teil 2, from the sterilising temperature of 160°C upto 180°C with closed air flap and door  

space deviation

cca °C

+5
-1

+5
-1

+5
-1

+5
-1

+5
-1

+5
-1

+5
-1

time variation

cca ± °C

+3
-1

+3
-1

+3
-1

+3
-1

+3
-1

+3
-1

+3
-1

Time required to reach 250 °C with closed air flap and voltage 230 V

 

cca min.

28

49

53

70

33

58

43

Heat emission at
250 °C

 

cca W

350

590

760

990

990

1940

1940

Air exchange speed at
150 °C

 

cca/hour

45

45

49

24

24

18

18

Electricity -mains 50/60 Hz

 

 

 

max. power input

cca kW

0,96

1,3

1,9

1,9

3,7

3,7

5,5

stand by

cca W

5

5

5

5

5

5

5

current

A

4,2

5,7
11,3

8,3
16,5

8,3
16,5

5,2; 5,2; 5,2

5,2; 5,2; 5,2 9,5; 9; 9
19,1; 18,1; 18,1

7,9; 7,9; 7,9

nominal voltage

V

230
115

230
115

230
115

230
115

400/3N

3x400+N+PE 3x230
3x115

400/3N

 

*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.
**) two-door (open-through) model

Note: All technical data are related to 22 °C ambient temperature and ± 10 % voltage swing (if not specified). Changes in the design and make reserved.