Thanks to patented system of forced air convention, the VENTICELL® line guarantees homogenous temperature distribution in all the drying and heating processes. Higher speed and precision of all the tempering procedures guarantees economical operation. Suitable mainly for high- humidity materials.
- Internal volume: 22, 55, 111, 222, 404, 707 litres (pass-through version except for the volume22 l)
- Temperature range: from 10°C above the ambient temperature up to 250/300°C
- Internal chamber: stainless steel DIN 1.4301 (AISI 304) Clean premises version – on request
The Eco Line:
- Intuitive control
- Microprocessor process control Fuzzy logic
- Multi-lingual communication
- Acoustic and visual alarm
- LED indicator of device functionality
- LCD display - 3 inches (7,6 cm)
- Transflective brilliant FSTN display, using COG technology (it is backlit and it uses external lighting reflection – higher intensity of external light increases the display readability)
- Adjustable display contrast depending on device placement
- Exceptionally wide vision angle
- Large signs on the display visible from afar
- Current values (eg. temperature, humidity for CLIMACELL®, pressure for VACUCELL®) during the device operation are enlarged for easy readibility
- Resistant foil keyboard with SoftTouch surface (pleasant to touch)
- Mechanic response of keys
- Lit symbols integrated directly in the foil keyboard
- Keyboard lock to block unauthorised access – adjustable by multiple pressing
- Real time programming and cycling (ramps as optional equipment)
- Up to 9 programs, 2 segments for each program and up to 99 cycles.
- USB Host port for flash disc connection for easy export of the relevant data (optional equipment)
Technical Specifications
Technical data |
|||||||||||||
Inner space |
volume |
l |
22 |
55 |
55-2 |
111 |
111-2 |
222 |
222-2 |
404 |
404-2 |
707 |
707-2 |
width |
mm |
240 |
400 |
400 |
540 |
540 |
540 |
540 |
540 |
540 |
940 |
940 |
|
depth |
mm |
320 |
370 |
370 |
370 |
370 |
520 |
520 |
520 |
520 |
520 |
540 |
|
height |
mm |
300 |
350 |
350 |
530 |
530 |
760 |
760 |
1410 |
1410 |
1410 |
1410 |
|
External dimensions ((including door, handle, legs N or casters K) |
width |
max. mm |
406 |
620 |
620 |
760 |
760 |
760 |
760 |
760 |
760 |
1160 |
1160 |
depth |
max. mm |
560 |
640 |
660 |
640 |
660 |
790 |
806 |
790 |
806 |
790 |
806 |
|
height |
max. mm |
610N |
680N |
680N |
860N |
860N |
1095N |
1110N |
1910K |
1910K |
1910K |
1910K |
|
ventilation neck diameter - internal / external |
mm |
52/49 |
52/49 |
52/49 |
52/49 |
52/49 |
52/49 |
52/49 |
52/49 |
52/49 |
52/49 |
52/49 |
|
Package – basic package |
width |
approx mm |
500 |
700 |
700 |
830 |
830 |
860 |
860 |
830 |
830 |
1230 |
1230 |
depth |
approx mm |
720 |
730 |
730 |
730 |
730 |
860 |
860 |
860 |
860 |
860 |
860 |
|
height (including palette) |
approx mm |
810 |
875 |
875 |
1060 |
1060 |
1260 |
1260 |
2085 |
2085 |
2085 |
2085 |
|
Package - case |
width |
approx mm |
720 |
780 |
780 |
810 |
810 |
920 |
920 |
910 |
910 |
1335 |
1335 |
depth |
approx mm |
780 |
800 |
800 |
910 |
910 |
960 |
960 |
970 |
970 |
1060 |
1060 |
|
height (including palette) |
approx mm |
835 |
900 |
900 |
1085 |
1085 |
1310 |
1310 |
2123 |
2123 |
2163 |
2163 |
|
Package – wooden crate |
width |
approx mm |
- |
780 |
780 |
900 |
900 |
900 |
900 |
910 |
910 |
1310 |
1310 |
depth |
approx mm |
- |
800 |
800 |
800 |
800 |
940 |
940 |
940 |
940 |
940 |
940 |
|
height (including palette) |
approx mm |
- |
870 |
870 |
1090 |
1090 |
1270 |
1270 |
2120 |
2120 |
2120 |
2120 |
|
Trays / shelves |
maximal number |
pc |
4 |
4 |
4 |
7 |
7 |
10 |
10 |
19 |
19 |
19 |
19 |
standard equipment |
pc |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|
minimal distance between trays/shelves |
mm |
60 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
|
usable area |
mm |
185×265 |
380×335 |
380×335 |
520×335 |
520×335 |
520×485 |
520×485 |
520×485 |
520×485 |
920×485 |
920x485 |
|
Maximal allowed loading of trays *) |
per 1 tray |
kg |
10 |
20 |
20 |
20 |
20 |
30 |
30 |
30 |
30 |
50 |
50 |
per 1 shelf |
kg |
10 |
20 |
20 |
20 |
20 |
30 |
30 |
30 |
30 |
20 |
20 |
|
inside the device - in total |
kg |
25 |
50 |
50 |
50 |
50 |
70 |
70 |
100 |
100 |
130 |
130 |
|
Number of external metal door |
pc |
1 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
2 |
4 |
|
Weight |
net |
approx kg |
31 |
55 |
60 |
75 |
80 |
100 |
105 |
150 |
160 |
215 |
230 |
gross (cartoon) |
approx kg |
36 |
66 |
71 |
87 |
92 |
116 |
121 |
175 |
185 |
240 |
255 |
|
Electric data – mains 50/60 Hz |
max. input |
kW |
0,96 |
1,3 |
1,9 |
1,9 |
2,5 |
1,9 |
3,7 |
3,7 |
5,5 |
4,9 |
7,3 |
stand by input |
W |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
|
current for voltage **) |
A |
4,2 |
5,6 |
8,3 |
8,3 |
10,6 |
8,3 |
5,6 |
5,6 |
8,3 |
7,8 |
15,6 |
|
V |
230 |
230 |
230 |
230 |
230 |
230 |
400/3NPE |
400/3NPE |
400/3NPE |
400/3NPE |
400/3NPE |
||
current for voltage **) |
A |
8,4 |
11,3 |
16,6 |
16,6 |
21,2 |
16,6 |
19 |
19 |
28 |
28 |
42 |
|
V |
115 |
115 |
115 |
115 |
115 |
115 |
115/3PE |
115/3PE |
115/3PE |
115/3PE |
115/3PE |
||
Degree of coverage |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
||
Temperature data |
|
|
|
|
|
|
|
|
|
|
|
||
Operation temperature |
from 10°C above ambient temperature |
to°C |
250/300 |
250/300 |
250/300 |
250/300 |
250/300 |
250/300 |
250/300 |
250/300 |
250/300 |
250/300 |
250/300 |
Variations from operation temperature with closed flap and door (DIN 12 880 part 2) |
space |
% temperature |
1,1 |
1 |
2 |
1 |
1 |
1 |
1,2 |
1,5 |
1,8 |
2,5 |
2,5 |
time |
±°C |
0,3 |
0,3 |
1,2 |
0,4 |
0,4 |
0,4 |
0,4 |
0,4 |
0,4 |
0,4 |
0,74 |
|
Time to reach temperature of 250°C with closed flap and voltage 230 V |
min |
28 |
49 |
- |
53 |
- |
70 |
33 |
58 |
43 |
64 |
50 |
|
Number of air exchanges at 250°C |
per hour |
45 |
45 |
45 |
49 |
49 |
24 |
24 |
18 |
18 |
12 |
12 |
|
Heat losses |
at 250°C |
W |
420 |
590 |
590 |
760 |
760 |
990 |
990 |
1940 |
1940 |
2550 |
2550 |
Note:
All the technical data apply to 22°C of ambient temperature and ± 10% voltage oscillation (unless stated otherwise). Standard version up to 250°C, optional version up to 300°C.
*) The trays may be covered to approximately 50% of their surface and if possibly in such a way so as the air may evenly flow inside the chamber space.
**) Mains voltage is specified on type label of the device.