ISO9001:2015 & ISO14001:2015
SciQuip Precision Multi-Parameter Water Quality Meter
Product Details
The SciQuip high accuracy multi-parameter water quality meter includes 15 parameters including pH, ORP, Ion concentration, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen of the liquids and is equipped with a large backlit LCD display.
SciQuip Precision Water Quality Multi Meter includes- P11 pH Electrode, K10 Conductivity Cell, DO 100 Polarographic probe, Electrolyte solution & Membrane Cap Kit, Temperature Probe, pH Buffer Pouches (pH4.01/7.00/10.01) , Calibration Solutions (84uS/cm, 1413uS/cm, 12.88mS/cm)
pH Mode:
- 1 to 5 points push-button calibration with auto-buffer recognition.
- Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
- Automatic electrode slope display helps user decide whether to replace sensor.
ORP Mode:
- Single point offset calibration allows adjusting the displayed value to a known standard.
- Relative and absolute millivolt measurement modes provide accurate ORP readings.
Ion Mode:
- 2 to 5 points calibration including the eight concentration calibration points can be selected.
- Automatically recognize ion selective electrodes, does not need to specify type of ion.
- Direct ion concentration readout simplifies the elaborate measurement process.
- Selectable multiple concentration units including the ppm, mg/L and mol/L.
Conductivity / TDS / Salinity / Resistivity Mode:
- 1 to 5 points push-button calibration with automatic calibration solution recognition.
- Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion factors, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
- 1 or 2 points calibration using air-saturated water and zero oxygen solution.
- Manual salinity and barometric pressure compensation improve the measurement accuracy.
Other Features:
- Automatic temperature compensation provides accurate reading over the entire range.
- Calibration due reminder prompts user to calibrate the meter regularly.
- Stability indicator automatically shows current measurement status.
- Auto-Hold function freezes stable measured value for easy viewing and recording.
- Manual temperature calibration corrects temperature deviation.
- Selectable temperature unit (°C or °F) meets different application requirements.
- Automatic electrode diagnosis shows zero point offset and slope of the electrode.
- Help message as an operational guide that helps you quickly begin using the meter.
- System menu allows setting the 15 parameters, including the calibration points, resolutions, stability conditions, measurement units, etc.
- Reset feature automatically resumes all parameters back to factory default options.
- Expanded memory stores and recalls up to 500 readings.
- Built-in real-time clock stamps stored data to meet GLP standard.
- Stored data can be transferred into computer by USB communication interface.
Technical Specifications
pH |
|
Range | -2.000~20.000pH |
Accuracy | ±0.002pH |
Resolution | 0.1, 0.01, 0.001pH |
Calibration Points | 1 to 5 points, USA, NIST, DIN Standards |
mV |
|
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1, 1mV |
Calibration Points | 1 point (Only for Relative mV mode) |
Ion |
|
Range | 0.001~19999ppm, mg/L, mol/L (Depending on range of ISE) |
Accuracy | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
Conductivity |
|
Range | 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Accuracy | ±0.5% F.S |
Calibration Points | 1 to 5 points |
Calibration Solutions | 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm |
Temperature Coefficient | 0.0~10.0%/°C |
Compensation Modes | Linear or Pure Water |
Cell Constant | K=0.1, 1, 10 |
Normalization Temperature | 20 or 25°C |
TDS |
|
Range | 0-10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) |
Accuracy | ±1% F.S |
TDS Factor | 0.1~1.0 (Default 0.5) |
Resolution | 0.01, 0.1, 1 |
Salinity |
|
Range | 0.00-80.00ppt, 0.00-42.00psu |
Accuracy | ±1% F.S |
Measurement Modes | Practical Salinity (psu) or Natural seawater (ppt) |
Resistivity |
|
Range | 0.00-20.00mΩ |
Accuracy | ±1% F.S |
Resolution | 0.01, 0.1, 1 |
Dissolved Oxygen |
|
Range | 0.00~20.00mg/L (or ppm) |
Accuracy | ±0.2mg/L |
Resolution | 0.01mg/L |
Calibration Points | 1 or 2 points |
Pressure Correction | 60.0~112.5kPa, 450~850mmHg |
Salinity Correction | 0~50g/L |
% Saturation of Oxygen |
|
Range | 0.0~200.0% |
Accuracy | ±2.0% |
Resolution | 0.1, 1% |
Temperature |
|
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Points | 1 point |
Calibration Range | Measured value ±10°C |
General Spec |
|
Hold Function | Manual or Auto-Endpoint |
Stability Conditions | Low or High |
Calibration Due | 1 to 31 days or Off |
Temperature Compensation | 0-100°C, 32-212°F, Manual or Automatic |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC, 6-pin Mini Plug |
Display | LCD |
Power Requirements | DC5V, using AC adapters, 220VAC/50Hz |
Unit Dimensions (LxWxH) | 210 x 188 x 60mm |
Packaged Dimensions (LxWxH) | 300 x 240 x 170mm |
Weight | 1.7kg |