Lauda Integral T Process Circulators

Product Details

LAUDA Integral T - Process thermostats for professional external temperature control in the temperature range of −25 to 120 °C

High-performance process thermostats for effective control of external temperature control processes

The mobile Integral T process thermostats have an adjustable heating and cooling capacity and small, active internal volume that enables fast temperature changes. The minimized thermal ballast makes it possible to control exothermal reactions or simulate climatic influences, for example. Starting with the T 4600 model, the Integral T's are equipped with an additional pump for independent internal circulation within the internal loop. An adjustable bypass valve between the inlet and outlet of the external loop also enables a reduction in pressure to protect, for example, pressure-sensitive consumers.

The T control unit can be easily folded out, making the following inter-faces accessible from below: Connector for standby contact input, fault (alarm) contact output, analog inputs and outputs, external Pt100 and serial RS-232-/485 interface. 

Important Function:

  • Fold-out control unit with large display and easily accessible interfaces
  • All devices come with castors
  • Filler nozzle on front, drain tap at the rear
  • Small stainless steel bath with large expansion volume
  • Programmer with max. 150 segments, 5 program parts
  • Automatic proportional cooling with compressor control

Included accessories:

  • Nipples for pump connections

Further accessories

  • Tubing
  • 4-port manifold

Pumps can be Upgraded - Please contact our Sales & Technical Team for full details. 

Technical Specifications

Model
Integral T 2200
Integral T 2200 W Integral T 4600 Integral T 4600 W Integral T 7000 Integral T 7000 W Integral T 10000 Integral T 10000 W
Working temperature min.
 -25 °C
 -25 °C
-30 °C
-30 °C
 -30 °C
 -30 °C
 -30 °C
 -30 °C
Working temperature max.
 120 °C
120 °C
 120 °C
 120 °C
120 °C
 120 °C
 120 °C
120 °C
Ambient temperature min.
 5 °C
5 °C
 5 °C
 5 °C
 5 °C
 5 °C
 5 °C
 5 °C
Ambient temperature max.
 40 °C
 40 °C
 40 °C
 40 °C
 40 °C
40 °C
40 °C
 40 °C
Temperature stability
 0.20 ±K
0.2 ±K
 0.20 ±K
 0.2 ±K
 0.3 ±K
0.3 ±K
 0.3 ±K
0.3 ±K
Filling volume min.
 3 L
3 L
 6 L
 6 L
 8 L
 8 L
8 L
 8 L
Filling volume max.
 7 L
 7 L
 18 L
18 L
20 L
20 L
20 L
 20 L
Cooling output at 20 °C measured with ethanol
 2.2 kW
2.7 kW
 4.6 kW
 5.5 kW
 7.0 kW
 8.5 kW
 10.0 kW
 13.0 kW
Cooling output at 10 °C measured with ethanol
 1.8 kW
2.3 kW
 3.7 kW
 4.5 kW
 6.0 kW
 7.0 kW
 9.0 kW
11.0 kW
Cooling output at 5 °C measured with ethanol
 1.6 kW
2.1 kW
 3.2 kW
4 kW
 5.5 kW
 6.3 kW
 8.2 kW
 9.9 kW
Cooling output at 0 °C measured with ethanol
 1.4 kW
1.9 kW
 2.8 kW
 3.4 kW
 5.0 kW
 5.5 kW
 7.3 kW
8.7 kW
Cooling output at -5 °C measured with ethanol
 1.2 kW
1.7 kW
 2.3 kW
 2.9 kW
 4.0 kW
4.7 kW
 6.2 kW
 7.4 kW
Cooling output at -10 °C measured with ethanol
 1.0 kW
1.4 kW
 1.9 kW
 2.3 kW
 3.0 kW
 3.9 kW
 5.1 kW
 6.0 kW
Cooling output at -15 °C measured with ethanol
 0.8 kW
1.0 kW
 1.3 kW
 1.7 kW
 2.4 kW
 3.0 kW
 4.1 kW 4.9 kW
Cooling output at -20 °C measured with ethanol
 0.6 kW
0.68 kW
 1.0 kW
 1.1 kW
 1.7 kW
 2.0 kW
 3.0 kW
3.7 kW
Cooling output at -25 °C measured with ethanol
 0.35 kW
0.42 kW
 0.5 kW
 0.65 kW
1.0 kW
 1.3 kW
 2.2 kW
2.6 kW
Cooling output at -30 °C measured with ethanol
 -
-
 0.2 kW
0.3 kW
 0.5 kW
0.6 kW
1.2 kW
 1.5 kW
Interface(s)
 RS-232/485
 RS-232/485
RS-232/485
 RS-232/485
RS-232/485
RS-232/485
 RS-232/485
RS-232/485
Application
 external
external
external 
external
 external
external
external
 external
Noise level
 60 dB(A)
58 dB(A)
 63 dB(A)
-
 65 dB(A)
 63 dB(A)
 69 dB(A)
67 dB(A)
Heater power
 2.25 kW
2.25 kW
 6.0 kW
 6.0 kW
6.0 kW
 6.0 kW
 9.0 kW
 9.0 kW
Loading
 3.1 kW
3.1 kW
 8.5 kW
 8.3 kW
 11.5 kW
 11.2 kW
 16.0 kW
 15.5 kW
Hose size
3/4"
3/4"
3/4"
-
 1"
 1"
 1"
 1"
Resolution of indication
 
-
Dimensions (WxDxH) in mm
 450x550x790
450x550x790
 550x650x970
 850x670x970
850x670x970
1050x770x1120
850x670x970
Pump pressure max.
 3.2 bar
3.2 bar
 3.2 bar
3.2 bar
 6.0 bar
6.0 bar
 6.0 bar
6.0 bar
Pump flow max. (pressure)
 40 L/min
40 L/min
 40 L/min
40 L/min
60 L/min
 60 L/min
 60 L/min
60 L/min
Pump connection thread
 G 3/4 (15)
 G 3/4 (15)
G 3/4 (15)
G 3/4 (15)
G 1 1/4 (20)
 G 1 1/4 (20)
 G 1 1/4 (20)
 G 1 1/4 (20)

Write a review of Lauda Integral T Process Circulators

*Your Review - Choose your star rating

Buying Options

Product Code Description List Price Offer Price
L001714 LAUDA Integral T 2200 - Process thermostat 230 V; 50 Hz POA Enquire
L001715 LAUDA Integral T 2200 W - Process thermostat 230 V; 50 Hz POA Enquire
L001720 LAUDA Integral T 4600 - Process therm. 400 V; 3/N/PE 50 Hz POA Enquire
L001721 LAUDA Integral T 4600 W - Process therm. 400 V; 3/N/PE 50 Hz POA Enquire
L001722 LAUDA Integral T 7000 - Process therm. 400 V; 3/N/PE 50 Hz POA Enquire
L001723 LAUDA Integral T 7000 W - Process therm. 400 V; 3/N/PE 50 Hz POA Enquire
L001724 LAUDA Integral T 10000 - Process therm. 400 V; 3/N/PE 50 Hz POA Enquire